Use este identificador para citar ou linkar para este item: https://rigeo.sgb.gov.br/handle/doc/17055
Registro completo
Campo DCValorIdioma
dc.contributor.authorBONOTTO, Giancarlo-
dc.date.accessioned2016-11-01T15:03:47Z-
dc.date.available2016-11-01T15:03:47Z-
dc.date.issued2016-
dc.identifier.citationBONOTTO, Giancarlo. A comparison of patchy saturation velocity models to ultrasonic tests. 2016. 125 f., il. Thesis (Master of Science)-John and Willie Leone Family Department of Energy and Mineral Engineering, The Pennsylvania State University, University Park, PA.pt_BR
dc.identifier.urihttps://rigeo.sgb.gov.br/handle/doc/17055-
dc.descriptionDissertação Mestrado em Ciências
dc.description.abstractCharacterization and monitoring of underground reservoir properties is of paramount importance for a multitude of disciplines. Acoustice wave velocity measurements, like in seismic surveys and well logs, are one of the most attractive approaches to gather informations about reservoir, as they provide reliable information with the needed spatial coverage and resolution required for many applications. Yet, the estimation of this parameter in partially saturated rocks can be a challenging assignment due to uncertainties associated with heterogeneities in fluid saturation. In order to analyze and interpret field data at partial saturation conditions, patchy saturation models are used to perform fluid substitution simulations, although commonly some of their underlying assumptions are deliberately ignored. Therefore, this work aims to experimentally investigate the performance of widely used patchy models (Gassmann-Voigt, White’s spherical and White et al. layered model) at controlled patchy saturation conditions. Patchy saturated samples were created in the laboratory using a simple saturating and stacking methodology and submitted to ultrasonic tests at two wave frequencies (100 and 250 kHz). From the laboratory data and predictions of the models, it was found that the models based on Biot’s theory seem to perform better, as they presented errors smaller than Gassmann-Voigt and are based on more realistic assumptions. Moreover, a simpler velocity average method appears to perform just as well, if not better, than these more complex and commonplace models, since it presented the smallest deviations from the experimentally measured velocities.pt_BR
dc.language.isoenpt_BR
dc.publisherThe Pennsylvania State Universitypt_BR
dc.rightsopenpt_BR
dc.subjectGEOFÍSICApt_BR
dc.subjectHIDROGEOFÍSICApt_BR
dc.subjectRESERVATÓRIOSpt_BR
dc.subjectMODELOS DE SATURAÇÃO IRREGULARpt_BR
dc.titleA comparison of patchy saturation velocity models to ultrasonic testspt_BR
dc.typeDissertationpt_BR
dc.localPennsylvania
Aparece nas coleções:Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
GB_Master_Thesis.pdf4,44 MBAdobe PDFThumbnail
Visualizar/Abrir


O uso do material disponibilizado neste repositório deve ser feito de acordo e dentro dos limites autorizados pelos Termos de Uso.